Removing and installing/replacing flat motor for rear left or right power windows (Cooper)
Preliminary work needed:
- Remove REAR POWER WINDOWS .
Release screw connections (1).
Remove flat motor (2) from power windows.
Cable must not come loose from power window.
Installation note:
Simultaneously tighten both screw connections (1).
The shaft of the flat motor (2) must be pulled into the holder of the power windows under slight tension.
Tightening torque 51 35 1AZ .
Flat motor (2) must engage exactly at the marked points of the power windows (1).
IMPORTANT:
Ensure that the flat motor (2) is assembled without tension.
After installation:
An initialization must be carried out in order to activate crush guard.