64 53 515 Replacing desiccant insert for air conditioning system
Special tools required:
WARNING:
Avoid contact with refrigerant and refrigerant oil.
Follow all applicable SAFETY INFORMATION .
IMPORTANT:
Risk of damage!
Restart engine only when A/C system has been correctly filled.
Restart engine only when A/C system has been correctly filled.
Necessary preliminary tasks:
Remove protective cap (1).
Remove circlip (1) and pull out desiccant insert (2).
Installation note:
Replace sealing rings.
Use special tool 00 9 030 to mount sealing rings without damaging them.
After installation:
- EVACUATE AND FILL air conditioning system.