24 35 508 Replacing wiring harness in automatic transmission (AISIN)
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
After completion of work, check TRANSMISSION FLUID LEVEL
.
Make a note of drained ATF quantity.
Required replenishment quantity approx. 4.5 liters.
Make a note of drained ATF quantity.
Required replenishment quantity approx. 4.5 liters.
IMPORTANT:
Use only the approved OPERATING FLUID
in this automatic transmission.
Do not drain fluid before the transmission has cooled down.
Do not drain fluid before the transmission has cooled down.
Necessary preliminary tasks
- Remove HYDRAULIC SELECTOR UNIT
Release screw (1).
Disconnect multiple connector (2) of EGS control unit.
Tightening torque: 24 11 19AZ .
Installation:
Coat O-ring with ATF.
Release screw (1).
Disconnect multiple connector (2) of EGS control unit.
Tightening torque: 24 11 19AZ .
Installation:
Coat O-ring with ATF.