24 30 010 Removing and installing/replacing hydraulic shift unit (AISIN)
Make a note of drained ATF quantity.
Required replenishment quantity approx. 4.5 liters.
Otherwise the automatic transmission may incur extensive damage!
Do not drain oil before the transmission has cooled down.
Necessary preliminary work
- Remove TRANSMISSION OIL SUMP
- Remove TRANSMISSION OIL STRAINER
Bend open retaining lugs (1) of hand valve lever.
Slacken nut (2).
Tightening torque: 24 11 17AZ .
Remove hand valve lever (3).
Release connectors (1/2) from holders and disconnect.
Release screw (1).
Tightening torque: 24 11 17AZ .
Remove oil temperature sensor (2) with locking plate (3).
Installation note:
Moisten seal with ATF.
Disconnect plugs of magnet and pressure valves.
Installation note:
Pay attention to routing of cables.
Numbers: 4, 6, 10, 12 = 28 mm.
Numbers: 2, 3, 5, 7, 8, 11 = 21 mm.
Numbers: 1, 9 = 16 mm.
First release screws uniformly in specified order and then remove.
Remove selector unit.
Installation note:
Pay attention to installation location of cable clip and cables.
Hold accumulator plunger (1) and spring firmly when removing selector unit.
Installation note:
Moisten accumulator plunger and spring with ATF.
Install selector unit, accumulator plunger and spring simultaneously.
Installation note:
Before installing selector unit, secure cable with adhesive tape in installation location on housing.
Jointing torque and angle of rotation must be observed.
Tightening torque: 24 11 18AZ .