LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 110 (Heating And Air Conditioning - Repair - S Clubman (R55)) >> Ac Housing-Evaporator >> 64 51... Leak-testing evaporator

64 51... Leak-testing evaporator

WARNING: This page is about a different variant/trim than selected.

Special tools required: 

WARNING: Comply with the standard national safety regulations on handling nitrogen.
Ensure that employees are advised of how to handle pressurized vessels and nitrogen correctly (danger of asphyxiation). For this purpose, follow the notes and instructions in the technical safety specifications available from the gas supplier.

Necessary preliminary tasks: 

Replace sealing rings (1) and coat with refrigerant oil.

Fig 1: Identifying Sealing Rings
G04792654Courtesy of BMW OF NORTH AMERICA, INC.

Connect special tool 64 5 125 to retaining clip and screws of expansion valve.

Tightening torque 64 11 5AZ

Fig 2: Identifying Special Tool (64 5 125) And Retaining Clip
G04792655Courtesy of BMW OF NORTH AMERICA, INC.

Connect special tool 64 5 121 to special tool 64 5 125 .

Fig 3: Identifying Special Tools (64 5 121) And (64 5 125)
G04792656Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Risk of damage: Use only nitrogen pressure bottles with pressure reducers for leak-testing.
Pressurize evaporator to 10 bar slowly  only. Excessively fast pressurization and pressures in excess of 20 bar may cause damage to the evaporator.

Connect nitrogen pressure bottle with pressure reducer to pressure gauge and then connect to special tool 64 5 121 (connecting hose).

NOTE:
  • Testing apparatus must be leakproof.
  • Ambient temperature and temperature of vehicle must not change during the test procedure.
  • Do not move the vehicle during this period

Apply test pressure of 10 bar slowly  and close nitrogen pressure bottle.

Check leak-tightness of testing apparatus and of connection to refrigerant line.

Set test pressure of 10 bar is only permitted to drop by 2 bar to 8.5 bar over a test period of 1.5 hours.

If the pressure loss is greater than 1.5 bar, this indicates that there is a leak in the evaporator unit.

WARNING: After leak-testing, unscrew special tool 64 5 121slowly  from special tool 64 5 125 to reduce pressure.

After leak-testing: