LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 544 (HEATING AND AIR CONDITIONING - REPAIR - X5 (3.0i)) >> A/C Housing/Evap., Switching Elements >> 64 51 580 Leak-testing evaporator

64 51 580 Leak-testing evaporator

WARNING: This page is about a different car, the 2003 BMW X5, 2002 BMW X5, and 2001 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

For Special Tool identification, see SPECIAL TOOLS - X5 (3.0i) .

Special Tools Required: 

Necessary Preliminary Tasks: 

Release screws (1), tightening torque, (18 N.m.).

Disconnect refrigerant lines (2).

Installation: 

Replace sealing rings.

Fig 1: Locating Refrigerant Lines
G03256773Courtesy of BMW OF NORTH AMERICA, INC.

Connect special tool 64 5 104 with special tool 64 5 105 and connect to suction line of refrigerant lines (2). Connect special tool 64 5 106 to pressure line of refrigerant lines (2).

Tighten screws (1) to specified tightening torque, (18 N.m.).

Fig 2: Attaching Sealing Adapters To Suction Line
G03256774Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Risk of damage: Use only nitrogen pressure bottles with pressure reducers for leak-testing. Pressurize evaporator to 15 bar slowly only. Excessively fast pressurization and pressures in excess of 20 bar may cause damage to the evaporator. Connect nitrogen pressure bottle with pressure reducer to pressure gauge and then connect to special tool 64 5 104 (connecting hose).
NOTE:
  • Testing apparatus must be leakproof.
  • Ambient temperature and temperature of vehicle must not change during the test procedure.
  • Do not move the vehicle during this period.

Slowly apply test pressure of 15 bar and close nitrogen pressure bottle.

Check leak-tightness of testing apparatus and of connection to refrigerant line.

Set test pressure of 15 bar is only permitted to drop by 2 bar to 13 bar over a test period of 2 hours.

If the pressure loss is greater than 2 bar, this indicates that there is a leak in the evaporator unit with expansion valve.