64 52... Instructions for compressor replacement
- Avoid impacts/knocks to plastic belt pulley (caused by tools, contact with base).
- Return faulty compressors in their original packaging only.
- Switch on Air conditioning system
- Set all air vents in instrument panel to "OPEN"
- Start engine and let it stabilize at idle speed
- Set blower output to min. 75% of max. blower output
- Switch on Air conditioning system and run for at least 2 minutes at idle speed (risk of damage at increased engine speed!)
When evacuating the air-conditioning system, refrigerant fluid is also extracted and collected in the oil separator of the service station.
After evacuation, the refrigerant must be filtered in the service station as the oil separator could still contain a liquid refrigerant/oil mixture. The filtering process gasifies the refrigerant completely and only the previously bound refrigerant fluid remains in the oil separator. Measure and note down this quantity of refrigerant fluid, REFER TO EVACUATING A/C SYSTEM .
Transfer the refrigerant fluid remaining in the previous compressor via the filler plug completely into a measuring cup.
Measure the amount of refrigerant fluid collected from the previous compressor.
The new compressor is filled at the factory with refrigerant fluid. Open filler plug and pour entire contents of compressor into a clean collecting vessel.
Installation note:
Replace sealing rings.
Use special tool 00 9 030 to mount sealing rings without damaging them.
Observe tightening torque, 64 52 2AZ. See A/C COMPRESSOR
From the new compressor, pour the same amount of refrigerant fluid (as drained from the previous compressor) + 10 g extra into a clean measuring cup and pour again into the new compressor.
Remaining refrigerant fluid can be poured into service station tank, REFER TO EVACUATING A/C SYSTEM .
Otherwise the excess refrigerant fluid must be disposed of correctly.
On account of its hygroscopic properties, refrigerant fluid must not be stored in open containers.
The refrigerant fluid drawn off from the oil separator of the service station and from the previous compressor must not be reused and must be correctly disposed of.
After installing the new compressor, it is essential before filling the A/C system to pour the same amount of the previously drawn off refrigerant fluid into the system again, REFER TO EVACUATING A/C SYSTEM .
Installation note:
If air conditioning system is opened for more than 24 hours: REPLACE DRYER FLASK/DESICCANT INSERT .