LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 2009 >> Mariner Base, 2.5 7, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 111 (Information Center - Instrument Cluster (Ic), Message Center, & Warning Chimes) >> Diagnostic Tests >> Instrument Cluster (Ic), Message Center And Warning Chimes >> Pinpoint Tests >> Pinpoint Test A: The Instrument Cluster (IC) Is Inoperative >> Pinpoint Test A: The Instrument Cluster (Ic) Is Inoperative

Pinpoint Test A: The Instrument Cluster (Ic) Is Inoperative

WARNING: This page is about a different car, the 2009 Mercury Grand Marquis and 2009 Ford Crown Victoria. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  1. A1 CHECK THE INSTRUMENT CLUSTER (IC) VOLTAGE SUPPLY 
    • Key in OFF position.
    • Disconnect: Instrument Cluster (IC) C2220
    • Key in ON position.
    • Measure the voltage between the instrument cluster (IC), harness side and ground as follows:
      Instrument Cluster (IC) Connector-Pin Circuit
      C2220-1 1523 (DG)
      C2220-17 1003 (GY/YE)
      C2220-19 640 (RD/YE)
    • Are the voltages greater than 10 volts? 
    1. YES  : Go to  A2.
    2. NO  : VERIFY the CJB fuses 2 (7.5A), 13 (10A) and 26 (10A) are OK. If OK, REPAIR the circuit in question. TEST the system for normal operation.
  2. A2 CHECK INSTRUMENT CLUSTER (IC) GROUND CIRCUITS 
    • Key in OFF position.
    • Measure the resistance between the instrument cluster (IC), harness side and ground as follows:
      Instrument Cluster (IC) Connector-Pin Circuit
      C2220-2 676 (PK/OG)
      C2220-18 57 (BK)
    • Are the resistances less than 5 ohms? 
    1. YES  : Go to  A3.
    2. NO  : REPAIR the circuit in question. TEST the system for normal operation.
  3. A3 CHECK FOR CORRECT INSTRUMENT CLUSTER (IC) OPERATION 
    • Disconnect the instrument cluster (IC) connector.
    • Check for:
      • corrosion
      • damaged pins
      • pushed-out pins
    • Connect the instrument cluster (IC) connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    1. YES  : INSTALL a new instrument cluster (IC). REFER to Instrument Cluster (IC) . TEST the system for normal operation.
    2. NO  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.