LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Electrical >> Horns >> Electrical System, Equipment & Instructions - Safety Precautions, Testing & Repair >> Testing & Repair >> Charge Battery - Ar54.10-D-1130TS

Charge Battery - Ar54.10-D-1130TS

Model 907 

  Risk of fire  /risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning  caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death  due to voltage U >= 30 V AC and U >= 60 V DC. No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. AS54.10-Z-0001-01A 
  Notes on battery   AH54.10-P-0001-01A
REMOVING Remove    
1 Remove battery to be charged. Remove on-board electrical system battery Model 907 AR54.10-D-0009TSR 
    Remove the auxiliary battery Model 907 with code E2I (Auxiliary battery for retrofitted consumers, interior) AR54.10-D-0007TS 
    Remove auxiliary battery in engine compartment Model 907 with code E2M (Auxiliary battery for retrofit consumers, engine compartment) AR54.10-D-0024TS 
    Remove additional battery for emergency shift park pawl Model 907 with code G42 (7G-TRONIC PLUS) except code EE5 (ULTRACAP - Automatic transmission lock)
Model 907
with code G43 (9G-TRONIC)
except code EE5 (ULTRACAP - Automatic transmission lock)
AR54.10-D-0120TSR 
INSPECT Check    
2 Check condition of battery.   AR54.10-D-1129TS 
  Charging    
3
REFER TO SPECIAL TOOLS
Connect positive terminal of charger to positive terminal of the battery. 000 588 00 81 00 Charger   WS54.00-P-0037B
4 Connect ground terminal of charger to negative terminal of battery.    
5 Charge battery. IMPORTANT Normal charging: Charging current up to max. 10 % of battery capacity, e.g. max. 6.0 A charging current for a 60 Ah battery.
Rapid charging: Charging current from 10 % to max. 50 % of battery capacity for 30 min, e.g. max. 30 A charging current for a 60 Ah battery.
Follow the operating instructions for the charger.
 
6 Disconnect ground clamp of charger from battery.    
7 Disconnect positive terminal of charger from battery.    
INSTALLING Install     
8 Install charged battery. Install on-board electrical system battery Model 907 AR54.10-D-0009TSR 
    Install additional battery Model 907 with code E2I (Auxiliary battery for retrofitted consumers, interior) AR54.10-D-0007TS 
    Install auxiliary battery in engine compartment Model 907
with code E2M (Auxiliary battery for retrofit consumers, engine compartment)
AR54.10-D-0024TS 
    Install additional battery for emergency shift park pawl Model 907 with code G42 (7G-TRONIC PLUS) except code EE5 (ULTRACAP - Automatic transmission lock)
Model 907
with code G43 (9G-TRONIC)
except code EE5 (ULTRACAP - Automatic transmission lock)
AR54.10-D-0120TSR