LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Accessories & Equipment >> Body Interior >> ELECTRICAL SYSTEM, EQUIPMENT & INSTRUCTIONS - BASIC KNOWLEDGE (1 of 2) >> Basic Knowledge >> Caravan Control Unit Parameters Of Analog Outputs, Function - GF54.21-D-5026TSA

Caravan Control Unit Parameters Of Analog Outputs, Function - GF54.21-D-5026TSA

Model 907 

with code JA3 (Intelligent body control.) 

General 

Analog outputs are used to set voltage values to, for example, control a device that executes corresponding actions depending on the voltage applied to its input.

The MB Advanced Control control unit (N175) can operate 5 analog outputs.

Parameters, analog outputs 

The analog outputs can switch a maximum of 10 V and a minimum of 250 mV.

The analog outputs have a resolution of 100 mV and a tolerance of 200 mV.

The analog outputs can supply a maximum of 2 mA.

The load on the analog outputs must be greater than 5 kOhm.

IMPORTANT As soon as the read voltage value does not match the output voltage, the MBAC switches off the analog output and creates an internal fault entry.

Caravan control unit configuration of analog outputs, function GF54.21-D-5021TSA 
Caravan control unit configuration of analog inputs, function GF54.21-D-5022TSA 
Caravan control unit configuration of digital outputs, function GF54.21-D-5023TSA 
Caravan control unit configuration of digital inputs, function GF54.21-D-5024TSA 
Caravan control unit parameters of analog inputs, function GF54.21-D-5025TSA 
Caravan control unit parameters of digital inputs, function GF54.21-D-5027TSA 
Caravan control unit parameters of digital outputs, function GF54.21-D-5028TSA 
Overview of system components of caravan control unit GF54.21-D-9992TSA