LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Body & Frame >> Body, Cab Control Systems >> ELECTRICAL SYSTEM, EQUIPMENT & INSTRUCTIONS - BASIC KNOWLEDGE (1 of 2) >> Basic Knowledge >> Caravan Control Unit Configuration Of Analog Inputs, Function - GF54.21-D-5022TSA

Caravan Control Unit Configuration Of Analog Inputs, Function - GF54.21-D-5022TSA

Model 907 

with code JA3 (Intelligent body control.) 

General 

Analog inputs are used to, e.g. read out the values of a sensor and to recognize any voltage thresholds.

The MB Advanced Control control unit (N175) can operate up to 17 analog inputs.

The MBAC consists of two stages, MBAC Stage I and MBAC Stage II.

The MBAC is designed to enable configuration of the assignment of the I/O interfaces. The assignment of the I/O interfaces is configured by the body manufacturer.

An example configuration for the assignment of the I/O interfaces with analog inputs is given below.

Assignment of I/O interfaces with analog inputs (example) 

Each stage has exactly one analog input "AI_Battery_Voltage".

Each stage has exactly one analog input "AI_Current_Flow_Difference".

Each stage has exactly one analog input "AI_HeatingJnterior_TempSensor".

Each stage has exactly one analog input "AI_Heating_Wet_Area_TempSensor".

Each stage has exactly one analog input "AI_Heating_Floor_TempSensor".

Each stage has exactly one analog input "AI_HeatingJnlet_TempSensor".

Each stage has exactly one analog input "AI_Heating_Outside1_TempSensor".

Each stage has exactly one analog input "AI_Heating_Outside2_TempSensor".

Each stage has exactly one analog input "AI_Hot_Water_TempSensor".

Each stage has exactly one analog input "AI_Fill_Level_Sensor_Fresh_Water".

Each stage has exactly one analog input "AI_Fill_Level_Sensor_Waste_Water".

Each stage has exactly one analog input "AI_Fill_Level_Sensor_Black".

Each stage has exactly one analog input "AI_Refrigerator_Box_TempSensor".

Each stage has exactly one analog input "AI_Awning_Pushbutton_Switch".

Each stage has exactly one analog input "AI_Rain_Sensor".

Caravan control unit configuration of analog outputs, function GF54.21-D-5021TSA 
Caravan control unit configuration of digital outputs, function GF54.21-D-5023TSA 
Caravan control unit configuration of digital inputs, function GF54.21-D-5024TSA 
Caravan control unit parameters of analog inputs, function GF54.21-D-5025TSA 
Caravan control unit parameters of analog outputs, function GF54.21-D-5026TSA 
Caravan control unit parameters of digital inputs, function GF54.21-D-5027TSA 
Caravan control unit parameters of digital outputs, function GF54.21-D-5028TSA 
Overview of system components of caravan control unit GF54.21-D-9992TSA