Caravan Control Unit Parameters Of Analog Inputs, Function - GF54.21-D-5025TSA

Model 907 

with code JA3 (Intelligent body control.) 

General 

Analog inputs are used to read out values, for example from a sensor, and to recognize voltage thresholds.

The MB Advanced Control control unit (N175) can operate up to 17 analog inputs.

Parameters, analog inputs 

The analog inputs can detect a maximum of 10 V and a minimum of 0 V.

The analog inputs have a resolution of 100 mV and a tolerance of 200 mV.

The input resistance is greater than 5 kOhm.