Remove/Install Augmented Reality Camera - AR54.30-P-0004S

Model 223 

with code U19 (Augmented reality video) 

G16191664Courtesy of MERCEDES-BENZ USA
Topical note  Information on preventing damage to electronic components due to electrostatic discharge   AH54.00-P-0001-01A
REMOVINGINSTALLING Remove/install     
1 Switch off ignition and store transmitter key outside of transmitter range (min. 2 m).    
2 Remove cover (1). SPECIAL TOOL Long wedge Fig 1
3 Disconnect electrical connection (2).    
4 Unhook spring clip (3) using suitable tool and remove camera for augmented reality (B84/14). NOTES
Do not touch lens of camera for augmented reality (B84/14).
Otherwise, soiling could result in the camera for augmented reality (B84/14) malfunctioning.
 
    INSTALLATION IMPORTANT First attach spring clip (3) to camera for augmented reality (B84/14).  
5 Install in the reverse order.    
6 Calibrate camera for augmented reality (B84/14) using diagnostic system.    
REFER TO SELF-DIAGNOSTIC SYSTEMS     AD00.00-P-2000-06FR
REFER TO SPECIAL TOOLS 000 588 11 21 00 Adjustment device   WS82.00-P-0151B
REFER TO SPECIAL TOOLS 000 588 00 23 00 Adjusting gauge   WS82.00-P-0028B
Fig 1: Identifying Long Wedge (115 589 03 59 00)
G07070400Courtesy of MERCEDES-BENZ USA