Update Instrument Cluster Control Unit Software - SM54.30-S-0021A
Model 447.60#/70# ## as of 001854 up to 028165
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES
| Category | Op. no. | Operation text | Time | Acc. no. | Code |
|---|---|---|---|---|---|
| P | 02 8890 | Operations: Update instrument cluster control unit software | - | 54 954 51 | VIVWARTINT |
| Check | |||
| 1 | Check whether vehicle is affected by measure | SM54.30-S-0021-01A | |
| 2 | Check whether the vehicle is affected by the "V2RAILDRUC" measure | If the vehicle is affected by the "V2RAILDRUC" measure and this measure has not yet been performed: ↓ First program the CDI control unit software. Model 447.6##/7## ## as of 001854 up to 033083 with engine 622 If the vehicle is not affected by the "V2RAILDRUC" measure or this measure has already been performed: ↓ continue with operation step 3. |
SM07.08-S-0027A |
| 3 | Print out DSB (Digital Service Booklet) service report from Input Process Output (EVA) system | ||
| 4 | Call up and note down service interval indicator using key combination via instrument cluster (IC) (A1/1) | ||
| 5 | Check values of service interval indicator against values from DSB (Digital Service Booklet) for plausibility | ||
| Update software | |||
| 6 | Connect diagnostic unit | If XENTRY Diagnostics is already connected to the vehicle: ↓ Proceed with step 7. |
|
| 7 | Connect battery charger | ||
| Maintaining on-board electrical system voltage when performing test and diagnosis work on vehicle | During the entire work procedure a sufficiently large voltage supply must be provided for the vehicle's on-board electrical system. Otherwise any undervoltage that occurs may damage the control units. |
AR54.10-S-1127E | |
| 8 | Program software of instrument cluster (IC) control unit (A1/1) | ||
| Programming of control units | Engine 622 with sheet 228.51 Engine 651 with sheet 229.51 |
AR54.21-S-0014E | |
| 9 | Clear fault memory | ||
| 10 | Disconnect diagnostic equipment | ||
| 11 | Disconnect battery charger | ||
| Maintaining on-board electrical system voltage when performing test and diagnosis work on vehicle | AR54.10-S-1127E | ||
| 12 | Withdraw ignition key | ||
| Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | AS00.00-Z-0005-01A | |
| 13 | Insert ignition key and start engine | ||
| 14 | Turn off engine | ||
| 15 | Call up service interval indicator using key combination via instrument cluster (IC) (A1/1) and compare with entries from DSB (Digital Service Booklet) |