Check Air Conditioning System For Leakage - AR83.30-P-1761GW

Model 463 

as of model year 2013 up to model year 2019 

MODIFICATION NOTES

31.10.2016 Test method changed Operation steps 2, 3  
31.10.2016 Leak tester added   WS83.00-P-0035B
31.10.2016 Gas detection unit added   WS47.00-P-0019B
31.10.2016 Safety note added   AS83.00-Z-0001-02A
31.10.2016 Safety note added   AS83.00-Z-0006-01A
31.10.2016 Safety note added   AS83.00-Z-0007-01A
31.10.2016 "Technical note" added   AH83.30-P-0005-01A
31.10.2016 General note added   AH83.30-P-0003-02A
  Risk of explosion  when using a forming gas with incorrect mixing ratio. Risk of suffocation  due to inhalation of forming gas. Risk of injury  due to bursting of high-pressure hoses. Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. AS83.00-Z-0001-02A
WARNING Risk of poisoning  caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury  to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. AS83.00-Z-0006-01A
  Risk of fire  due to ignition of R1234yf refrigerant on hot components. Risk of poisoning  caused by inhaling overheated refrigerant vapors. Risk of injury  to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion  due to formation of ignitable refrigerant/air mixtures Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. AS83.00-Z-0007-01A
WARNING Risk of accident  from vehicle starting off by itself when engine running. Risk of injury  (bruises and burns) resulting from working on the engine while it is being started or when it is running. Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. AS00.00-Z-0005-01A
  Procedure for a damaged or leaky air conditioning system   AH83.30-N-0004-01A
  Protect air conditioning circuit and components from moisture when carrying out repair work   AH83.30-N-0005-01A
  Notes on handling refrigerant R134a   AH83.30-N-0003-01A
  Notes on handling refrigerant R1234yf   AH83.30-P-0003-02A
  Draining     
1 Drain air conditioning system Model 463 (except 463.270/271)
as of model year 2013 up to model year 2019
AR83.30-P-1760GW 
INSPECT Check     
2 Charge the high- and low-pressure sides of the air conditioning system with forming gas when the engine is cold to a system pressure of 15 bar    
REFER TO SPECIAL TOOLS 000 588 19 21 00 Leak tester IMPORTANT The leak tester operator's manual must be observed.
IMPORTANT The system pressure must be maintained for at least 4 h.
IMPORTANT Temperature changes during the pressure test can cause pressure surges, e. g. due to weather changes, transition from day to night, cooling down of engine compartment.
Ensure that the ambient conditions are identical.
WS83.00-P-0035B
3 Check refrigerant circuit of air conditioning system for leaks using gas detection unit If a pressure drop is determined.  
REFER TO SPECIAL TOOLS 000 588 03 21 00 Gas detector If a leak is detected in the refrigerant circuit

Drain forming gas and replace damaged refrigerant circuit components.
If no leak is detected in the refrigerant circuit:

Drain the forming gas and check evaporator for leaktightness, replace if necessary.
WS47.00-P-0019B
    Model 463
as of model year 2013 up to model year 2019
AR83.30-P-5550GW 
FLUID SPECIFICATION Filling     
4 Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak Model 463 (except 463.270/271)
as of model year 2013 up to model year 2019
AR83.30-P-1760GW