LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> C300 Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 146 (Overall Vehicle - 213 Chassis 6 Of 8) >> Capacities & Specifications >> Coolant Specifications - BB00.40-P-0310-01A

Coolant Specifications - BB00.40-P-0310-01A

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2023 Mercedes-Benz E63 S AMG, 2023 Mercedes-Benz E53 AMG, 2023 Mercedes-Benz E350, 2022 Mercedes-Benz E53 AMG, and 2022 Mercedes-Benz E350. However, it is still accessible from the selected car via links, so may be relevant.

Model all 

    Specified anti-corrosion protection/antifreeze (Cars, VAN) - Overview Model all (4xWD, CAR, Light transporter, smart) BB00.40-P-0320-01A 
    Specified anti-corrosion protection/antifreeze (CV) - Overview Model all (BUS, Heavy transporter, TRUCK, UNIMOG) BB00.40-P-0320-02A 
NOTE: These specifications apply to the Mercedes-Benz, Maybach, AMG, smart, and Setra brands.
WARNING: The tasks that the antifreeze with corrosion inhibitor, coolants or coolant additives have to perform are as important as those of a component. All products that are not listed in the following Specifications for Operating Fluids Specification sheets do not have MB approval and can thus lead to significant restrictions  in the engine output and/or to irreparable damage  to the engine cooling system.
  1. Terms used 

    Antifreeze with corrosion inhibitor: 

    Also known as "concentrate". It is part of the coolant for combustion engines, antifreeze with corrosion inhibitor, used for lowering the freezing point and raising the boiling point. Must be mixed with water as per item 3.4.

    Coolant: 

    Mixture of concentrate (or antifreeze) and water for cooling engines.

    Coolant additives: 

    Anticorrosion agent that can be used for special applications mixed with water. The mixture has no antifreeze protection!

    MB approval: 

    Identification of coolant and corrosion/antifreeze that are approved for use in vehicles/major assemblies of the Mercedes-Benz brand. The application area must be complied with in accordance with Specifications for Operating Fluids Specification sheets 320.1 and 320.2. On the containers for tested products, you can find the term "MB-Freigabe XXX.X  " or "MB-Approval XXX.X  " as a note.

  2. Overview and Specifications for Operating Fluids Specification sheets 

    The antifreezes listed in the following Specifications for Operating Fluids Specification sheets guarantee the following important properties:

    • Ensure heat transfer
    • Long-term corrosion and cavitation protection for all component parts of the engine cooling system
    • Long-term compatibility with all component parts of the engine cooling system
    • Ensure antifreeze protection
    • Increase boiling point
    • Resistant against microorganisms
    • Effective foam suppression

    For an overview of the approved Specifications for Operating Fluids Specification sheets for cars and vans, see Specifications for Operating Fluids Specification sheet 320.1.

    For an overview of the approved Specifications for Operating Fluids Specification sheets for commercial vehicles and buses, see Specifications for Operating Fluids Specification sheet 320.2.

    The following information must be observed: 

    The products specified in Specifications for Operating Fluids 325.x are antifreezes. They must  be mixed with water as per item 3.4 before they are used.

    The products specified in Specifications for Operating Fluids 326.x are coolants. They must not  be mixed with water.

    The products listed in the Specifications for Operating Fluids 325.7/326.7 are not  compatible with the products listed in the other Specifications for Operating Fluids Specification sheets.

    Fuel cell vehicles require a special coolant for cooling. Coolants for fuel cell vehicles must only be refilled in an F-Cell support point.

  3. Mixing Ratio 
    1. 3.1. Specification sheets 326.x 

      The products listed in the Specifications for Operating Fluids 326.x are coolants or finished mixtures and must not be mixed with water. When using them (except products from Specifications for Operating Fluids 326.64), compliance with the concentration (50/50) must be ensured in addition to the MB approval (see item 5).

      In the case of products for the AMG GT Black Series (Specifications for Operating Fluids 326.64), the special concentration 40 percent by volume concentrate/60 percent by volume water (± 2 percent by volume) must be observed in addition to the MB approval.

    2. 3.2. Specification sheets 325.x 

      All concentrates or antifreezes listed in Specification sheets 325.x must be used with approx. 50 % by volume of water. This mixing ratio is important for, e.g.:

      • The freezing point
      • The boiling point
      • Heat dissipation
      • The portion of anti-corrosion protection

      The water quality must satisfy the requirements listed in item 3.4. Even with extremely low ambient temperatures, not more than 55 vol.-% antifreeze is to be used. With 55 % by volume of antifreeze, the maximum antifreeze protection, approx. -45°C, of an aqueous ethylene glycol solution is achieved; a higher antifreeze portion reduces antifreeze protection and heat dissipation in the engine, which can cause irreparable damage. If the coolant contains less than 45% by volume or more than 55% by volume of antifreeze with corrosion inhibitor in the coolant, the mixing ratio must be corrected immediately (see item 5).

      TARGET CONCENTRATION OF ANTIFREEZE WITH CORROSION INHIBITOR AND WATER

      Specification sheet No. 312.0 325.0/3/5/6/7
      Mixing ratio  Concentrate % by volume  10 50
        Water % by vol.  90 50
    3. 3.3. Specification sheet 312.0 

      In special cases (commercial vehicle engines, no antifreeze requirement, see Specifications for Operating Fluids Specification sheet 320.2), coolant additives can be used that are essentially anticorrosion additives. The products must be mixed with 90 % by volume of water.

      Mixtures of different products as stated in Specification sheet 312.0 are not permitted.

    4. 3.4. Water quality 

      Clean and the softest possible water should be used for processing the coolant. Drinking water often satisfies the requirements.

      Information concerning the water quality of drinking water is available from the local water-plant authorities or the official water utilities on request.

      If there is no available information regarding the water quality or if no suitable water is available, then distilled or deionized water should be used to prepare the coolant. Sea water, brackish water, brine and industrial waters are not suitable. Salts may promote corrosion or form disruptive deposits.

      The analysis values of the water for mixing coolants must be within the limits of table 2.

    WATER QUALITY

    Water quality min max
    Earth alkali ions mmol/l   2, 7
    Hardness °dH   15
    Chloride mg/l   80
    Chloride + sulfate mg/l   160
    pH-value - 6, 5 8, 0

    1°dH = 0.1783 mmol/l alkaline earth ions = 7.147 mg/l Ca 2+ or 4.336 mg/l Mg 2+

  4. Ingredients 

    The coolants and antifreezes with corrosion inhibitor are based on ethylene glycol as the antifreeze component, but differ with regard to the remaining ingredients, e.g. for corrosion protection; see Table 3 .

    SPECIFICATIONS FOR OPERATING FLUIDS SPECIFICATION SHEET NUMBER AND COOLANT TYPE

    Coolant Specification sheet no. Antifreeze with corrosion inhibitor Specification sheet no. Inhibitors Free of
        inorganic organic  
    326.0  325.0  Si, B X Nitrite, amine, phosphate
    326.3  325.3    X Nitrite, amine, phosphate, borat, silicate
    326.5  325.5  SI X nitrite, amine, phosphate, borat, 2-ethylhexanoic acid
    326.6/64  325.6/64  SI X nitrite, amine, phosphate, borat, 2-ethylhexanoic acid
    326.7  325.7    X Nitrite, amine, borate, silicate
  5. Monitoring coolant operation 

    During operation, the corrosion inhibitors of the coolant are consumed and the mixing ratio may change due to water evaporation. It is therefore very important to regularly monitor the coolant if the engine is to run trouble free.

    The inspection of the mixing ratio should be conducted with suitable apparatus. To do this, the density or the refractive index can be used to determine this according to Table 4 . For individual coolants, the information on the mixing ratio may vary slightly from the values given in Table 4 .

    If the coolant contains less than 45% by volume or more than 55% by volume of antifreeze with corrosion inhibitor, the mixing ratio must be immediately corrected  . The following calculation aid can be used to calculate the top-up quantity.

    CONCENTRATION/ANTIFREEZE PROTECTION/DENSITY/REFRACTIVE INDEX (APPROX.)

    Concentration  vol %  20 25 30 35 40 45 50
    Freezing point  °C  -9 -12 -16 -20 -25 -32 -37
    Density (20°C)  g/cm 3  1, 029 1, 037 1, 045 1, 052 1, 060 1, 067 1, 073
    Refractive index n  20°  1, 355 1, 360 1, 366 1, 371 1, 376 1, 382 1, 387

    Calculation of coolant quantity to be added for low concentration (Specified: 50 Vol.-%) 

    • Coolant content (total) in liters
    • Measured concentration in Vol.-%

    Computational formula:

    • (50 - measured concentration) * coolant content/(100 - measured concentration) = top-up quantity for corrosion/antifreeze

    Example of calculation:

    • Coolant content (total) = 8 liters
    • Measured concentration = 36 Vol.-%
    • (50 % - 36 %) * 8 l/(100 % - 36 %) = 1.75 liters

    This calculated quantity should normally be drained off beforehand

  6. Disposal of coolants 

    The coolants are biologically-degradable material. The statutory regulations or waste water ordinances in each individual country must be observed when disposing of used coolant. It is recommended to have the possibilities available for disposing of materials explained by the local responsible water authorities.