Check Air Conditioning System For Leakage - Ar83.30-D-1761TS
Model 907, 910
MODIFICATION NOTES
| 18.07.2019 | Basic data reference BE08.50-N-1001-02TE, added | Operation step 2 |
| Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. Model 910 with engine 780.703 | ||
| Risk of explosion when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury due to bursting of high-pressure hoses. | Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. | AS83.00-Z-0001-02A | |
| General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | AH00.00-Z-0300-01A | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | AH83.30-N-0005-01A | ||
| Procedure for a damaged or leaky air conditioning system | AH83.30-N-0004-01A | ||
| Check | |||
| 1 | Discharge and evacuate air conditioning system. | AR83.30-D-1760TS | |
| 2 | Fill air conditioning with forming gas and check pressure drop. | ||
| 000 588 19 21 00 Leak tester | Make sure ambient temperatures remain constant. Otherwise, temperature changes during the pressure test (e.g. caused by a change in the weather or cooling down of the engine compartment over night) may cause pressure fluctuations. |
WS83.00-P-0035B | |
| Model 907 Pressure drop in refrigerant circuit filled with test gas If a pressure drop was detected, ↓ locate leakage in air conditioning system using gas detection unit. |
*BE83.30-N-1001-04TS | ||
| 000 588 03 21 00 Gas detector If a leak is present, ↓ replace affected air conditioning system component parts. |
WS47.00-P-0019B | ||
| 3 | Vent used forming gas from refrigerant circuit using leak tester. | ||
| 4 | Fill air conditioning. | AR83.30-D-1760TS |
AIR CONDITIONING
| Number | Designation | Model 907 | ||
|---|---|---|---|---|
| BE83.30-N-1001-04TS | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 |
| Test period | h | 4 | ||
| Permissible ambient temperature fluctuation | °C | ±2 | ||
| Pressure drop | bar | 0 | ||