Remove/Install Extinguishing Agent Tank - AR86.10-P-0100LFS
Model 222.1
with code Z21 (Fire extinguishing system)
| Topical note | Notes on squib on extinguishing agent tank | Model 222.1 with Code Z07 (Maximum protection) with Code Z21 (Fire extinguishing system) | AH86.10-P-0001-04A |
| Notes on aerosol extinguishing agent tank | Model 222.1 with Code Z07 (Maximum protection) with Code Z21 (Fire extinguishing system) | AH86.10-P-0001-02A | |
| Remove | |||
| 1 | Switch off ignition and remove transmitter key | ||
| 2 | Open paneling (7) on extinguishing agent tank (1) | ||
| 3 | Unscrew safety pin (8) from valve body (9) | ||
| 4 | Use safety pin (8) and screw into valve body (9) | Otherwise the extinguishing agent tank (1) is not secured. |
|
| *BA86.10-P-1008-01B | |||
| 5 | Remove fuse 4 from fuse box I, rear right wheel well | ||
| 6 | Disconnect electrical connectors from extinguishing agent tank (1) | ||
| Notes for extinguishing agent tank pressure monitor switch | AH86.10-P-0001-03A | ||
| 7 | Unscrew union nut (3) and carefully remove extinguishing agent pipe (4) from connector (6) on extinguishing agent tank (1) | ||
| 8 | Open hose clamps (2) | ||
| 9 | Remove extinguishing agent tank (1) | ||
| Install | |||
| 10 | Install extinguishing agent tank (1) in bracket | ||
| 11 | Close bolt clamps (2) | ||
| 12 | Carefully guide extinguishing agent tube (4) into connection piece (6) and tighten union nut (3) | *BA86.10-P-1003-01B | |
| 13 | Connect electrical connectors to extinguishing agent tank (1) | ||
| Notes for extinguishing agent tank pressure monitor switch | AH86.10-P-0001-03A | ||
| 14 | Insert fuse 4 into fuse box i, right rear wheel arch | ||
| 15 | Unscrew safety pin (8) from valve body (9) | ||
| 16 | Use safety pin (8) and screw into valve body (9) | Otherwise the extinguishing agent tank (1) is not operational. |
|
| *BA86.10-P-1008-01B | |||
| 17 | Close paneling (7) on extinguishing agent tank (1) | ||
| Check | |||
| 18 | Perform self-test for fire extinguishing system | AR86.10-P-0101-01LFS |
FIRE EXTINGUISHING SYSTEM
| Number | Designation | MODEL 222.1/9 with CODE Z07 and CODE Z21 | ||
|---|---|---|---|---|
| BA86.10-P-1003-01B | Threaded connections for extinguishing agent lines | Size 14 | Nm | 12 |
| Size 17 | Nm | - | ||
| Size 19 | Nm | - | ||
FIRE EXTINGUISHING SYSTEM
| Number | Designation | MODEL 222.1/9 with CODE Z07 and CODE Z21 | |
|---|---|---|---|
| BA86.10-P-1008-01B | Locking pin to extinguishing agent tank | Nm | 6 |