Check Air Conditioning System For Leakage - AR83.30-P-1761LF
Model 217, 222
| Risk of explosion when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury due to bursting of high-pressure hoses. | Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. | AS83.00-Z-0001-02A | |
| Notice | Procedure for a damaged or leaky air conditioning system | AH83.30-P-0004-01KOA | |
| Check | |||
| 1 | Evacuate air conditioning system | AR83.30-P-1760LF | |
| 2 | Preliminary test for pressure drop test | Model 217, 222 with code 1U6 (R744 refrigerant) |
|
| 000 588 19 21 00 Leak tester | WS83.00-P-0035B | ||
| Preliminary test for pressure drop test | *BE83.30-P-1002-04A | ||
| 3 | Fill air conditioning with forming gas and check pressure drop | ||
| 000 588 19 21 00 Leak tester | WS83.00-P-0035B | ||
Consistent ambient conditions must therefore be strictly ensured. |
|||
| Pressure drop in refrigerant circuit filled with test gas | *BE83.30-P-1001-04A | ||
| 4 | Check for leaks in air conditioning system using gas detection unit | If a drop in pressure is detected. | |
| 000 588 03 21 00 Gas detector | WS47.00-P-0019B | ||
↓ Replace damaged components of the air conditioning system. |
|||
| 5 | Release forming gas from leak tester | ||
| 6 | Charge air conditioning system | AR83.30-P-1760LF |
AIR CONDITIONING
| Number | Designation | Model 118, 164, 166 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 216, 218, 219, 221, 230, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293 Model 213, 217, 222 except code 1U6 (R744 refrigerant) | Model 213, 217, 222 with code 1U6 (R744 refrigerant) | ||
|---|---|---|---|---|---|
| BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 | 90 |
| Test period | h | 4 | 4 | ||
| Permissible fluctuation of ambient temperature | °C | ±2 | ±2 | ||
| Pressure drop | bar | 0 | <1 | ||
AIR CONDITIONING
| Number | Designation | Model 213, 217, 222 with code 1U6 (R744 refrigerant) | ||
|---|---|---|---|---|
| BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | 50 |
| Test period | min | 1 | ||