LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2019 >> S450 Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - 222 Chassis (2 Of 4) >> Testing & Repair >> Check Air Conditioning System For Leakage - AR83.30-P-1761LF

Check Air Conditioning System For Leakage - AR83.30-P-1761LF

Model 217, 222 

DANGER Risk of explosion  when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury  due to bursting of high-pressure hoses. Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. AS83.00-Z-0001-02A
Notice  Procedure for a damaged or leaky air conditioning system   AH83.30-P-0004-01KOA
INSPECT Check     
1 Evacuate air conditioning system   AR83.30-P-1760LF 
2 Preliminary test for pressure drop test Model 217, 222
with code 1U6 (R744 refrigerant)
 
REFER TO SPECIAL TOOLS 000 588 19 21 00 Leak tester   WS83.00-P-0035B
    IMPORTANT Pay attention to the leak tester operator's manual.
IMPORTANT Do not fill air conditioning system with forming gas unless engine is cold.
 
    Preliminary test for pressure drop test *BE83.30-P-1002-04A 
3 Fill air conditioning with forming gas and check pressure drop    
REFER TO SPECIAL TOOLS 000 588 19 21 00 Leak tester   WS83.00-P-0035B
    IMPORTANT Pay attention to the leak tester operator's manual.
IMPORTANT Do not fill air conditioning system with forming gas unless engine is cold.
IMPORTANT Temperature changes during the pressure test (e.g. through change in weather or cooling down of the engine compartment overnight) can cause pressure surges.
Consistent ambient conditions must therefore be strictly ensured.
 
    Pressure drop in refrigerant circuit filled with test gas *BE83.30-P-1001-04A 
4 Check for leaks in air conditioning system using gas detection unit If a drop in pressure is detected.  
REFER TO SPECIAL TOOLS 000 588 03 21 00 Gas detector   WS47.00-P-0019B
    IMPORTANT Pay attention to the operator's manual of the leak tester and the gas detection unit. In the event of leakage

Replace damaged components of the air conditioning system.
 
5 Release forming gas from leak tester    
6 Charge air conditioning system   AR83.30-P-1760LF 
AIR CONDITIONING

Number Designation Model 118, 164, 166 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 216, 218, 219, 221, 230, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293 Model 213, 217, 222 except code 1U6 (R744 refrigerant) Model 213, 217, 222 with code 1U6 (R744 refrigerant)
BE83.30-P-1001-04A Pressure drop in refrigerant circuit filled with test gas Test pressure bar 15 90
Test period h 4 4
Permissible fluctuation of ambient temperature °C ±2 ±2
Pressure drop bar 0 <1
AIR CONDITIONING

Number Designation Model 213, 217, 222 with code 1U6 (R744 refrigerant)
BE83.30-P-1002-04A Preliminary test for pressure drop test Test pressure bar 50
Test period min 1