Remove/Install Expansion Reservoir For Window Lifter Hydraulic System - AR72.10-P-0013LF
Model 222
with code Z07 (B7 armoring on special protection version)
| Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure. Risk of poisoning from swallowing hydraulic fluid. | Depressurize hydraulic system completely before starting any work on it. Wear protective clothing and safety glasses. | AS00.00-Z-0013-01A | |
| Remove/install | |||
| 1 | Remove front door lining | AR72.10-P-1000LF | |
| 2 | Release pressure in pressure reservoir for hydraulic power window in rear door | AR72.10-P-1800-06LFS | |
| 3 | Remove bolts (3) | ||
| 4 | Remove expansion reservoir (1) | ||
| 5 | Detach hydraulic line (2), drain and collect oil from the expansion reservoir (1) | ||
| 6 | Install in the reverse order | ||
| 7 | Bleed window lifter hydraulic system | ||
| Hydraulic fluids (Specification 345.0) | BB00.40-P-0345-00A | ||
| AR72.10-P-0018-01LF |