Check Condition Of Battery - AR54.10-P-1129GZ
Model 164, 166, 292
MODIFICATION NOTES
| 14.06.2017 | Condition extended | Operation step 3 | |
| 10.05.2019 | Battery capacity 70 Ah VRLA/AGM | BE54.10-P-1010-01A |
| Risk of fire /risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Check | |||
| 1 | Perform visual inspection for external leakage | In the event of leakage ↓ replace on-board electrical system battery. |
AR54.10-P-0005GZ |
| 2 | Check on-board electrical system battery | Cold cranking amps as per EN | AR54.10-P-1129-01A |
| Battery capacity 70 Ah VRLA/AGM | *BE54.10-P-1010-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1015-01A | ||
| Fig 2 | |||
| 3 | Reduce increased voltage after charging process | For an on-board electrical system battery that is disconnected from the on-board electrical system, and shows the message "Surface voltage detected" or test voltage greater than 12.8V in the display of the Midtronics battery/test equipment. | |
| AR54.10-P-1129-03A | |||
| Fig 1 | |||
| 4 | Charge on-board electrical system battery | If test code "Charge and test" is shown on the Midtronics battery tester and analysis device MCR 717. | |
| AR54.10-P-1130GZ |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 720 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |