Check Battery - AR54.10-P-1129-01A
Model 117, 124, 126, 129, 140, 156, 163, 164, 166, 168, 169, 170, 171, 172, 176, 199, 201, 202, 203, 204, 207, 208, 209, 210, 211, 212, 215, 216, 218, 219, 220, 221, 230, 231, 240, 242, 245, 246, 251, 292, 451, 453, 461, 463
Model 190
except Code U98 (LITHIUM-ION STARTER BATTERY (LISB))
Model 197
except Code P98 (Black Series)
Model 205
except Code P25 (BlueEFFICIENCY Edition)
except Code U98 (LITHIUM-ION STARTER BATTERY (LISB))
Model 213, 238, 253
except Code U98 (LITHIUM-ION STARTER BATTERY (LISB))
Model 217 (except 217.37/47)
Model 222 (except 222.077/176/177/178/179/187/188)
Model 257
Model 290
Model 293
| Risk of fire/explosion due to short circuit and escaping oxyhydrogen gas.Risk of burns/risk of injury from eyes, skin and mucous membranes being burned by battery electrolyte/mist, short circuits and the effects of electric arcs. Risk of poisoning by swallowing battery electrolyte or absorbing lead through the skin or body orifices. Risk of death from electrical voltages U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Pour battery acid only into suitable and appropriately labeled containers. | AS54.10-Z-0001-01A | |
| Notice | Notes on battery | AH54.10-P-0001-01A | |
| 000 588 02 19 00 Battery tester | WS54.00-Z-3006KOB |
| 10.05.2019 | Battery capacity 70 Ah VRLA/AGM | BE54.10-P-1010-01A |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 660 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 720 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 800 |
| Number | Designation | Model all (4xWD, CAR, smart) | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |
Whenever possible, perform tests with the battery installed and connected.
If when testing, the battery tester shows a "Surface voltage detected" message, this indicates an increased voltage.
- Switch off the ignition and keep the transmitter key out of the range of the transmitter (at least 2 m).
- Switch off lighting and audio components.
- Connect the battery charger to the battery.
Do not connect the battery tester to jump start or charging terminal point, always connect it directly to the battery.
Otherwise the test result may be incorrect.
Once the battery tester is connected, the current measured battery voltage is displayed.
For system noise,
↓
Wait approx. 2 min until the bus systems are switched off and the quiescent current is minimized.
- Carry out the test procedure according to the menu instructions of the battery tester.
- After testing, print out the displayed test code and store it in an tamper-proof manner.