MODIFICATION NOTES

22.02.2021 Document completely revised.    

Example illustration 

G13747789Courtesy of MERCEDES-BENZ USA
REMOVING Remove     
1 Switch off ignition and store transmitter key outside of transmission range (min. 2 m).    
2 Remove engine compartment lining underneath condensation drain. Model 213 AR61.20-P-1105LWE
    Model 205
Model 253
AR61.20-P-1105LW
    Model 293 AR61.20-P-1105EQ
3 Place a receptacle under condensation drain. IMPORTANT Dispose of collected cleaner properly.  
4 Protect electronic component parts in cleaning area against moisture.    
5.1
REFER TO MAINTENANCE
Remove activated charcoal particle filter. Model 205, 213, 253, 293 with code 581 (Automatic climate control)  
    Model 205 with code 581 (Automatic climate control) AP83.00-P-8384CAA
REFER TO MAINTENANCE   Model 213, 253 with code 581 (Automatic climate control) AP83.00-P-8384B 
REFER TO MAINTENANCE   Model 293 with code 581 (Automatic climate control) AP83.00-P-8350C
5.2 Remove temperature sensor from evaporator. Model 205, 213, 253, 293 with code 580 (Air-conditioning system) AR83.30-P-8085LW 
6 Cover working area with absorbent cloths IMPORTANT Cleaner must not enter the vehicle interior  
CLEAN Clean     
7.1 Clean evaporator through opening of activated charcoal particle filter. Model 205, 213, 253, 293 with code 581 (Automatic climate control)
IMPORTANT Use entire content of cleaner.
AR83.30-P-5555-02MA 
    Pressure-feed spray gun with 2 cleaning probes (short and long) for A/C systems *BR00.45-Z-1081-04A 
    Cleaner for A/C system *BR00.45-Z-1084-04A 
7.2 Clean evaporator through opening of temperature sensor. Model 205, 213, 253, 293 with code 580 (Air-conditioning system) except code 581 (Automatic climate control)
IMPORTANT Use entire content of cleaner.
AR83.30-P-5555-02MB 
    Pressure-feed spray gun with 2 cleaning probes (short and long) for A/C systems *BR00.45-Z-1081-04A 
    Cleaner for A/C system *BR00.45-Z-1084-04A 
8 Check if any cleaner is discharged through the condensation drain. If no cleaner is discharged from the condensation drain,
↓
clean condensation drain.
 
9 Clean housing of activated charcoal particle filter and adjacent air ducts using a microfiber cloth. Cleaner for A/C system *BR00.45-Z-1095-04A 
INSTALLING Install     
10.1
REFER TO MAINTENANCE
Install activated charcoal particle filter. Model 205, 213, 253, 293 with code 581 (Automatic climate control)  
    Model 205 with code 581 (Automatic climate control) AP83.00-P-8384CAA
    Model 213, 253 with code 581 (Automatic climate control) AP83.00-P-8384B 
    Model 293 with code 581 (Automatic climate control) IMPORTANT Replace activated charcoal particle filter. AP83.00-P-8350C
10.2 Install temperature sensor on evaporator. Model 205, 213, 253, 293 with code 580 (Air-conditioning system) AR83.30-P-8085LW 
11 Remove cloths.    
12 Remove receptacle.    
13 Install engine compartment lining under condensation drain. Model 213 AR61.20-P-1105LWE
    Model 205
Model 253
AR61.20-P-1105LW
    Model 293 AR61.20-P-1105EQ
  Ventilate     
WARNING Risk of burn injuries,  suffocation and poisoning when working on the exhaust system and the components connected to it. Risk of suffocation and risk of poisoning caused by inhalation of gaseous and solid components of the exhaust. Risk of poisoning  caused by skin contact with solid components of the exhaust. Wear protective clothing and safety glasses. Use the extraction system. Move people out o the hazard area. AS49.00-Z-0001-01A
WARNING Risk of accident  from vehicle starting off by itself when engine running. Risk of injury  (bruises and burns) resulting from working on the engine while it is being started or when it is running. Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. Model 205, 213, 253 AS00.00-Z-0005-01A
14 Open all doors on vehicle.    
15 Start engine.    
16 Switch on air conditioning system, set air distribution to center air vent and let blower run for 5 min at the highest setting.    
17 Set air distribution to defroster, center and footwell vents and run blower at highest setting for 5 min.    
18 Switch off engine and close all doors.    
REPAIR MATERIALS

Number Designation Order number
BR00.45-Z-1081-04A Pressure-feed spray gun with 2 cleaning probes (short and long) for A/C systems A 000 581 00 04
BR00.45-Z-1084-04A Cleaner for A/C system A 000 989 46 00 09