LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2018 >> SLC43 AMG >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instruments - 172 Chassis - 2 Of 4 >> Testing & Repair >> Charge Battery - AR54.10-P-1130V

Charge Battery - AR54.10-P-1130V

Model 171, 172 

INSPECT Check    
  Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A 
1 Check condition of on-board electrical system battery Not with active transport mode. AR54.10-P-1129V 
  Charging    
2 Connect charger to on-board electrical system battery NOTES
Make sure that the vent hose and stop plugs of the battery or on-board electrical system battery are installed in the correct position. otherwise escaping battery acid will damage the vehicle.
NOTES
Do not reverse polarity. Risk of short circuit!
 
3
REFER TO SPECIAL TOOLS
Charge on-board electrical system battery 000 588 00 81 00 Charger IMPORTANT The battery charging period is dependent on the charge level of the discharged battery. The battery is sufficiently charged when the displayed charging current shown is < 25 A. WS54.00-P-0037B
4 Disconnect battery charger NOTES
Switch off charger beforehand. Risk of arcing.
 
INSPECT Check    
5 Check condition of on-board electrical system battery Not with active transport mode. AR54.10-P-1129V