(Remove/Install Left Temperature Sensor Upstream Of Nox Storage Catalytic Converter - AR14.40-P-0006MND)
Engine 276.853 in model 213
| Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. Deburr repair panels. |
AS00.00-Z-0017-01A | |
| Risk of injury . Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | AS00.00-Z-0002-01A | |
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Notes on avoiding damage through contamination and foreign objects | AH00.00-P-5000-01A | ||
| Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | AH00.00-P-0015-01CW | ||
| Remove | |||
| 1 | Release left underfloor paneling in area of electrical connections | AR61.30-P-1001LWE | |
| 2 | Release and disconnect electrical connection of temperature sensor (32) | ||
| 3 | Unclip electrical line from the brackets | ||
| 4 | Remove temperature sensor (32) | ||
| 5 | Cover temperature sensor (32) with a protective cover | When reusing the temperature sensor (32). | |
| Fig 1 | |||
| 6 | Close of threaded hole of the temperature sensor (32) using a suitable stop plug | Fig 2 | |
| 7 | Check temperature sensor (32) with electrical line | For damage ↓ Replace temperature sensor (32). |
|
| Install | |||
| 8 | Remove protective cover from temperature sensor (32) | When reusing the temperature sensor (32). | |
| Fig 1 | |||
| 9 | Remove stop plug from threaded hole of the temperature sensor (32) | Fig 2 | |
| 10 | Coat thread of the temperature sensor (32) with heat-resistant lubricant | When reusing the temperature sensor (32). | |
| Paste, hot lubrication 1 kg, DBL 6879.20 | *BR00.45-Z-1005-06A | ||
| 11 | Position temperature sensor (32) and fasten | *BA07.04-P-1003-01E | |
| 12 | Put together electrical connection of temperature sensor (32) and lock | ||
| 13 | Clip electrical line into holder | ||
| 14 | Fasten the left underfloor paneling | AR61.30-P-1001LWE | |
| Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | AS00.00-Z-0005-01A | |
| 15 | Perform an engine test run and check exhaust system for leaktightness |
NOX SENSOR
| Number | Designation | Engine 276 | |
|---|---|---|---|
| BA07.04-P-1003-01E | NOx temperature sensor to exhaust pipe | Nm | 45 |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1005-06A | Paste, hot lubrication 1 kg, DBL 6879.20 | A 000 989 76 51 |