Remove/install additional battery - AR54.10-P-0007RK
MODEL 231
| Remove/install | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Remove right side paneling in rear | AR68.30-P-4780RK | |
| 2 | Switch off ignition and remove transmitter key (A8/1) or KEYLESS-GO start/stop button (S2/3) from electronic ignition lock control unit (N73) | ||
| 3 | Remove frame (9) at stowage compartment | ||
| 4 | Unscrew bolts (1) and remove bracket (2) | ||
| 5 | Unscrew bolt (3) and detach ground line (4) from ECO start/stop function additional battery (G1/13) | *BA54.10-P-1004-01F | |
| 6 | Using diode test lamp, check on-board electrical system for voltage between positive line (5) of ECO start/stop function additional battery (G1/13) and detached ground line (4) | ↓ Disconnect/connect battery ground line |
AR54.10-P-0003RK |
| 7 | Unscrew bolt (6) and detach positive line (5) from ECO start/stop function additional battery (G1/13) | *BA54.10-P-1004-01F | |
| 8 | Release retaining tabs (7) and fold up cover (8) (arrow) | ||
| 9 | Disconnect vent hose from ECO start/stop function additional battery (G1/13) | ||
| 10 | Remove ECO start/stop function additional battery (G1/13) | ||
| 11 | Install in the reverse order |
BATTERY
| Number | Designation | MODEL 231 | |
|---|---|---|---|
| BA54.10-P-1004-01F | Screw/bolt, battery cable to battery terminal on additional battery | Nm | 5 |