LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2016 >> S550 Base >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Electrical System, Equipment & Instruments - 222 Chassis >> Testing & Repair >> Check condition of additional battery - AR54.10-P-1128LF

Check condition of additional battery - AR54.10-P-1128LF

MODEL 222 (except 222.07/17) 

Fig 1: Battery Box Lid, Additional Battery, Battery Box And ECO Start/Stop Function Additional Battery
G11132665Courtesy of MERCEDES-BENZ USA
DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses.
Only pour battery acid into suitable and appropriately marked containers.
AS54.10-Z-0001-01A
DANGER Risk of injury  caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof. No parts of the body or limbs should be within the operating area when the components are moving. AS00.00-Z-0011-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
IMPORTANT Notes on sensor system for trunk lid opening/closing Model 222 (except 222.07/17)
with code P17 (KEYLESS-GO package)
AH80.61-P-0001-01A
REMOVING Remove     
1 Remove cover of battery box (1) from battery box of additional battery (2) Model 222 (except 222.07/17)
except code Z07 (Top protection)
AR54.10-P-0007LF 
Model 222.1 (except 222.17), 222.9
with code Z07 (Top protection)
AR54.10-P-0111LFS 
INSPECT Check     
2 Visually inspect additional battery for ECO start/stop function (G1/13) for any external leakage In the event of leakage

Replace additional battery for ECO start/stop function (G1/13)
Model 222 (except 222.07/17)
except code Z07 (Top protection)
AR54.10-P-0007LF 
Model 222.1 (except 222.17), 222.9
with code Z07 (Top protection)
AR54.10-P-0111LFS 
3 Test additional battery for ECO start/stop function (G1/13) using tester   AR54.10-P-1129-01A
REFER TO SPECIAL TOOLS 000 588 02 19 00 Battery tester   WS54.00-N-3006B 
    Battery capacity 12 Ah *BE54.10-P-1017-01A 
    Battery capacity 12 Ah *BE54.10-P-1001-01A 
4
REFER TO SPECIAL TOOLS
Charge additional battery for ECO start/stop function (G1/13) directly at additional battery and check again with battery tester
000 588 00 81 00 Charger
If "Charge and test" is shown on battery testing device. WS54.00-P-0037B 
INSTALLING Install     
5 Mount cover for battery box (1) to battery box additional battery (2) Model 222 (except 222.07/17)
except code Z07 (Top protection)
AR54.10-P-0007LF 
Model 222.1 (except 222.17), 222.9
with code Z07 (Top protection)
AR54.10-P-0111LFS 
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation Model all
BE54.10-P-1001-01A Battery capacity 12 Ah Cold cranking amps As per EN A 170
TEST AND ADJUSTMENT VALUES FOR BATTERY

Number Designation Model all
BE54.10-P-1017-01A Battery capacity 12 Ah Cold cranking amps As per EN A 200