Check condition of additional battery - AR54.10-P-1128LF
MODEL 222 (except 222.07/17)
Fig 1: Battery Box Lid, Additional Battery, Battery Box And ECO Start/Stop Function Additional Battery
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof. | No parts of the body or limbs should be within the operating area when the components are moving. | AS00.00-Z-0011-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| Notes on sensor system for trunk lid opening/closing | Model 222 (except 222.07/17) with code P17 (KEYLESS-GO package) |
AH80.61-P-0001-01A | |
| Remove | |||
| 1 | Remove cover of battery box (1) from battery box of additional battery (2) | Model 222 (except 222.07/17) except code Z07 (Top protection) |
AR54.10-P-0007LF |
| Model 222.1 (except 222.17), 222.9 with code Z07 (Top protection) |
AR54.10-P-0111LFS | ||
| Check | |||
| 2 | Visually inspect additional battery for ECO start/stop function (G1/13) for any external leakage | In the event of leakage ↓ Replace additional battery for ECO start/stop function (G1/13) Model 222 (except 222.07/17) except code Z07 (Top protection) |
AR54.10-P-0007LF |
| Model 222.1 (except 222.17), 222.9 with code Z07 (Top protection) |
AR54.10-P-0111LFS | ||
| 3 | Test additional battery for ECO start/stop function (G1/13) using tester | AR54.10-P-1129-01A | |
| 000 588 02 19 00 Battery tester | WS54.00-N-3006B | ||
| Battery capacity 12 Ah | *BE54.10-P-1017-01A | ||
| Battery capacity 12 Ah | *BE54.10-P-1001-01A | ||
| 4 |
Charge additional battery for ECO start/stop function (G1/13) directly at additional battery and check again with battery tester 000 588 00 81 00 Charger |
If "Charge and test" is shown on battery testing device. | WS54.00-P-0037B |
| Install | |||
| 5 | Mount cover for battery box (1) to battery box additional battery (2) | Model 222 (except 222.07/17) except code Z07 (Top protection) |
AR54.10-P-0007LF |
| Model 222.1 (except 222.17), 222.9 with code Z07 (Top protection) |
AR54.10-P-0111LFS |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all | |||
|---|---|---|---|---|---|
| BE54.10-P-1001-01A | Battery capacity 12 Ah | Cold cranking amps | As per EN | A | 170 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all | |||
|---|---|---|---|---|---|
| BE54.10-P-1017-01A | Battery capacity 12 Ah | Cold cranking amps | As per EN | A | 200 |