Check condition of battery - AR54.10-P-1129LF
MODEL 217 (except 217.37/47)
MODEL 222 (except 222.07/17)
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes for 12-V lithium-ion battery | AH54.10-P-0004-01A | ||
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on sensor system for trunk lid opening/closing | AH80.61-P-0001-01A | ||
| Remove | |||
| 1 | Expose on-board electrical system battery | Model 217.4 (except 217.47) | AR54.10-P-0005LCA |
| Model 217.3 (except 217.37) | AR54.10-P-0005LC | ||
| Model 222 (except 222.07/17) except code ME04 (Mild hybrid drive) |
AR54.10-P-0005LF | ||
| Model 222 (except 222.07/17) with code ME04 (Mild hybrid drive) |
AR54.10-P-0005LFA | ||
| Check | |||
| 2 | Visually inspect on-board electrical system battery for external leakage | In the event of leakage ↓ Replace on-board electrical system battery Model 217.4 (except 217.47) |
AR54.10-P-0005LCA |
| Model 217.3 (except 217.37) | AR54.10-P-0005LC | ||
| Model 222 (except 222.07/17) except code ME04 (Mild hybrid drive) |
AR54.10-P-0005LF | ||
| Model 222 (except 222.07/17) with code ME04 (Mild hybrid drive) |
AR54.10-P-0005LFA | ||
| 3 | Check on-board electrical system battery using test equipment | AR54.10-P-1129-01A | |
| 000 588 02 19 00 Battery tester | WS54.00-N-3006B | ||
| Battery capacity 105 Ah | *BE54.10-P-1018-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1015-01A | ||
| 4 | Charge and check on-board electrical system battery | If the test code "Charge and check" is displayed on the battery tester/Midtronics tester. | |
| 000 588 00 81 00 Charger | WS54.00-P-0037B | ||
| Model 217 (except 217.37/47), 222 (except 222.07/17) | AR54.10-P-1130LF | ||
| 5 | Reduce increased voltage after charging process | with an on-board electrical system battery, which is disconnected from the on-board electrical system, the message "surface voltage detected" in the display of the Midtronics battery test/test equipment. | AR54.10-P-1129-03A |
| 000 588 03 19 00 Load tester | WS15.00-P-0027B | ||
| Install | |||
| 6 | Install parts that were removed to expose the on-board electrical system battery | Model 217.4 (except 217.47) | AR54.10-P-0005LCA |
| Model 217.3 (except 217.37) | AR54.10-P-0005LC | ||
| Model 222 (except 222.07/17) except code ME04 (Mild hybrid drive) |
AR54.10-P-0005LF | ||
| Model 222 (except 222.07/17) with code ME04 (Mild hybrid drive) |
AR54.10-P-0005LFA |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | Model all | |||
|---|---|---|---|---|---|
| BE54.10-P-1018-01A | Battery capacity 105 Ah | Cold cranking amps | As per EN | A | 950 |