Charge Air Cooling Circulation Pump, Location/Task/Function - GF09.41-P-3102M: Notes
Engine 275.950 In Model 215, 220
Engine 275.951 In Model 230
Engine 275.953 In Model 216, 221
Engine 275.954 In Model 230
Engine 275.980 In Model 215, 220
Engine 275.981 In Model 230
Engine 275.982 In Model 216, 221
Engine 285.950 In Model 240
Engine 285.980 In Model 240
| Charge air cooling circulation pump, arrangement | Model 215, 220 | GF09.41-P-3102-01K | |
| Model 216, 221 | GF09.41-P-3102-01MS | ||
| Model 230 | GF09.41-P-3102-01RA | ||
| Model 240 | GF09.41-P-3102-01M | ||
| Charge air cooling circulation pump task | Keep the charge air temperature below 70°C by means of coolant circulation. | ||
| Charge air cooling circulation pump function | The circulation pump is actuated via a relay by the engine control unit. Switching on: Charge air temperature above approx. 47°C Switching off: Charge air temperature below approx. 35°C |