Checking regulator and alternator - AR15.40-P-5000SX
ENGINE 156, 272, 273, 275, 629, 642 in MODEL 221
ENGINE 156, 273, 275 in MODEL 216
| Checking | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on avoiding damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A | ||
| Notes on battery | AH54.10-P-0001-01A | ||
| 1 | Check battery status | AR54.10-P-1129SX | |
| 2 | Connect up STAR DIAGNOSIS (0100) to data link connector (X11/4). | STAR DIAGNOSIS diagnosis system | |
| Connect STAR DIAGNOSIS | AD00.00-P-2000-04A | ||
| Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns during starting procedure or when working near the engine as it is running | Secure vehicle to prevent it from moving by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. |
AS00.00-Z-0005-01A | |
| 3 | Check alternator using STAR DIAGNOSIS (0100) | Tests are menu-assisted:
|
|
| 4 | Disconnect STAR DIAGNOSIS (0100). |