Charge battery - AR54.10-P-1130GZ
MODEL 164
| Check | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Check condition of battery | AR54.10-P-1129GZ | |
| Charging | |||
| 2 | Connect charger to battery | ||
| 3 | Charge battery | 50 % of battery capacity for 30 min: e.g. max. 50 A charging current for a 100 Ah battery. |
|
| 4 | Disconnect battery charger | ||
| Checking | |||
| 5 | Test battery after charging, see:↓ | ||
| Check condition of battery | AR54.10-P-1129GZ |