LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2008 >> CL550 >> Repair and Diagnosis >> Engine Mechanical >> Exhaust >> Exhaust System -- Cl550 -- 216 Chassis >> Basic Knowledge >> Monitoring catalytic converter efficiency, function - GF49.10-P-3033MIS

Monitoring catalytic converter efficiency, function - GF49.10-P-3033MIS

ENGINES 272.9 in MODEL 221.0 /1 as of model year 2009/YoM 08 

ENGINES 273.9 in MODEL 216.3, 221.0 /1 as of model year 2009/YoM 08 

Function requirements for monitoring catalytic converter efficiency, general points 

Monitoring catalytic converter efficiency, general points 

Hydrocarbon (HC) emissions should not exceed the limit specified by the legal requirements. The purpose of monitoring the catalytic converter efficiency is to evaluate the oxygen storage capacity of the firewall catalytic converters in order to obtain an indication of aging, and therefore of HC conversion.

For this purpose, the ME-SFI [ME] control unit (N3/10) reads the following sensors:

IMPORTANT

The oxygen stored during the "lean operating phase" is then reduced totally or partially during the "rich operating phase". With aging, the oxygen storage capacity of firewall catalytic converter is reduced, and so therefore is HC conversion.

Changes in the oxygen content downstream of the firewall catalytic converters are almost completely dampened by the high oxygen storage capacity of the firewall catalytic converters.

Consequently, the signals from the oxygen sensors downstream of firewall catalytic converters have low amplitude and are virtually constant.

Monitoring catalytic converter efficiency, function sequence 

When firewall catalytic converters are at operating temperature and the lambda control is enabled, the signal amplitudes of the oxygen sensors upstream of the firewall catalytic converters are compared with those downstream.

If the firewall catalytic converters are no longer operational, the oxygen sensor signals from the O 2 sensors upstream of catalytic converter and from the O 2 sensors downstream of catalytic converter are the same size.

A number of measurements take place in the lower partial-load range in the specified engine RPM range.

The results are compared with a performance map in the ME-SFI [ME] control unit.

Any faults detected are stored in the fault memory of the ME-SFI [ME] control unit. These can be read out and deleted with the Diagnosis Assistance System (DAS).

If a fault is detected, the ME-SFI control unit actuates the engine diagnosis indicator lamp (A1e58) on the instrument cluster (A1) through the chassis CAN (CAN E) and central CAN (CAN F).

REFER TO SYSTEM WIRING DIAGRAMS Electrical function schematic for monitoring of catalytic converter efficiency Model 216
Model 221
PE49.10-P-2050-97CAB 
PE49.10-P-2050-97SAB
  ME-SFI [ME] control unit, component description N3/10 Engine 272 except 272.974 (hybrid) GF07.61-P-6000MIS
    N3/10 Engine 272.974 (hybrid) GF07.61-P-6000MEH
    N3/10 Engine 273 GF07.61-P-6000MLS