Remove/install additional battery relay - AR54.15-P-2000TX
MODEL 219.3 up to 31.5.06
| Remove/install | |||
| 1 | Remove the water collector until the additional battery relay (K57/2) is accessible | AR83.25-P-1402TX | |
| 2 | Disconnect ground cable from additional battery | AR54.10-P-0007TX | |
| 3 | Separate electrical connector (1) from additional battery relay (K57/2) | ||
| 4 | Mark electrical lines (3), unscrew nuts (2) and remove electrical lines (3) | ||
| *BA54.10-P-1010-01C | |||
| 5 | Unscrew nuts (4) and remove additional battery relay (K57/2) | *BA54.10-P-1011-01C | |
| 6 | Install in the reverse order |
BATTERY
| Number | Designation | Model 219.3 | ||
|---|---|---|---|---|
| BA54.10-P-1010-01C | Nut, relay of additional battery to body | M6 | Nm | 8 |
| BA54.10-P-1011-01C | Nut, line connection to relay of additional battery | M6 | Nm | 7 |