Check condition of battery - AR54.10-P-1129TX
MODEL 211, 219
MODIFICATION NOTES
| 25.4.07 | Check fluid level with service fill level indicator added | Step 4.2 |
| Removing | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Remove trunk floor covering from trunk. | ||
| 2 | Remove spare tire cover or spare tire well trim panel from trunk | ||
| Check | |||
| 3 | Inspect battery and additional battery for external leaks | In the event of leakage: Replace battery, see:↓ Remove/install battery |
|
| Model 219 | AR54.10-P-0005TX | ||
| Model 211.0 | AR54.10-P-0005T | ||
| Model 211.2/6 Remove/install additional battery |
AR54.10-P-0005TA | ||
| Model 211 up to 31.5.06 | AR54.10-P-0007T | ||
| Model 219 up to 31.5.06 | AR54.10-P-0007TX | ||
| Dispose of battery | OS54.10-P-0001-01Z | ||
| 4.1 | Check fluid level in battery, replenish with distilled water if necessary | Without service fill level indicator, not on absorbent glass mat battery. | |
| 4.2 | Check fluid level of battery | With service fill level indicator, not on absorbent glass mat battery. | |
Remove/install battery |
|||
| Model 219 | AR54.10-P-0005TX | ||
| Model 211.0 | AR54.10-P-0005T | ||
| Model 211.2/6 | AR54.10-P-0005TA | ||
| 5 | Check battery | AR54.10-P-1129-01A | |
| Cold cranking amps as per EN | |||
| Battery capacity 12 Ah | *BE54.10-P-1001-01A | ||
| Battery capacity 60 Ah VRLA | *BE54.10-P-1006-01A | ||
| Battery capacity 70 Ah VRLA | *BE54.10-P-1010-01A | ||
| Battery capacity 74 Ah | *BE54.10-P-1011-01A | ||
| Battery capacity 90 Ah VRLA | *BE54.10-P-1014-01A | ||
| Battery capacity 95 Ah VRLA | *BE54.10-P-1015-01A | ||
| Battery capacity 100 Ah | *BE54.10-P-1016-01A | ||
| Midtronics battery tester with test clamps | Battery test/test equipment | ||
| 6 | Reduce increased voltage after charging process | On a battery that is disconnected from the on- board electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester. | AR54.10-P-1129-03A |
| Midtronics battery tester with test clamps | Battery test/test equipment |
||
| 7 | Charge battery | With the test code "Charge and check" on the Midtronics battery tester. | AR54.10-P-1130T |
| Install | |||
| 8 | Install spare tire cover or spare tire well paneling in luggage compartment | ||
| 9 | Place luggage compartment floor cover in luggage compartment and close luggage compartment |
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | All models | |||
|---|---|---|---|---|---|
| BE54.10-P-1001-01A | Battery capacity 12 Ah | Cold test current | as per EN | A | 170 |
| BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA | Cold test current | as per EN | A | 680 |
| BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA | Cold test current | as per EN | A | 760 |
| BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1.24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0.04 | |||
| Load current | A | 265 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 680 | ||
| BE54.10-P-1014-01A | Battery capacity 90 Ah VRLA | Cold test current | as per EN | A | 950 |
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold test current | as per EN | A | 850 |
| BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20°C | Acid density | kg/dm3 | ≥1.24 |
| Maximum permissible difference between individual battery cells | kg/dm3 | 0.04 | |||
| Load current | A | 300 | |||
| Load time | s | 10 | |||
| Voltage | VV | ≈10 | |||
| Cold test current | as per EN | A | 760 | ||