Remove/install clock spring contact - AR46.10-P-0200PQ
MODEL 203 as of 24.4.04, 209 as of 1.6.04
Shown on model 203
| Remove/install | |||
|---|---|---|---|
| Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | AS91.00-Z-0001-01A | |
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| 1 | Removing jacket tube module (N80) | AR54.25-P-2802PQ | |
| 2 | Detach switch pods (1, 2, 3, 4) | ||
| 3 | Remove bolts (5) | ||
| 4 | Detach fanfare horns and airbag clock spring contact (A45) | ↓ Turn the fanfare horns and airbag clock spring contact (A45) counterclockwise as far as the limit stop (turn gently against the limit stop, risk of damage), then turn approx. 2.5 turns clockwise until the screws are visible (5). |
|
| 5 | Unclip clamp screw (6) | ||
| 6 | Install in the reverse order | ||
| 7 | Perform basic programming | Model 203 | AR00.19-P-0200P |
| Model 209 | AR00.19-P-0200Q | ||
| 8 | Read out fault memory and erase | ||
| 9 | Carry out function check |