LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> CLK55 >> Repair and Diagnosis >> External Pages >> Different car >> Section 317 (Electrical System, Equipment & Instructions -- CLK350 Coupe (209.356)) >> Testing & Repair >> Treatment of battery if vehicle taken out of service - AR54.10-P-0006P

Treatment of battery if vehicle taken out of service - AR54.10-P-0006P

WARNING: This page is about a different car, the 2009 Mercedes-Benz CLK350 and 2008 Mercedes-Benz CLK350. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 203, 209 

DANGER Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A 
1 Check battery, charge battery if necessary   AR54.10-P-1129P 
2.1 Disconnect battery ground cable IMPORTANT When the vehicle is laid up for more than 4 weeks. This prevents the battery being discharged by closed-circuit accessories.  
Model 209 AR54.10-P-0003Q 
3 Charge battery IMPORTANT When battery is disconnected every 6 months at the latest and when the battery is connected every 6 weeks at the latest. AR54.10-P-1130P