Definition 

Desychronization  makes the counter status for the position measurement  invalid.

Function 

Desynchronization occurs when: 

In all these cases, the relationship between the counter status in the overhead control panel control module (N70) and the actual position of the sliding/pop-up roof (SR) (M12) is no longer correct. For this reason synchronization  is required.

IMPORTANT In the desynchronized state operation of the sliding/pop-up roof (SR) (M12) is limited.

It is then only possible to open  the sliding/pop-up roof, whereby actuation of the SR motor (M12m1) is only possible for a short time, max. 1 s. For further actuation the switch must be released and actuated again

  Synchronize sliding/pop-up roof, function   GF77.20-P-3002S 
  Sliding/pop-up roof lock-up recognition, function   GF77.20-P-3000S 
  Sliding/pop-up roof position measurement, function   GF77.20-P-3001A 
  Sliding/pop-up roof obstruction sensor, function   GF77.20-P-3004S 
  Sliding/pop-up roof, location/purpose/design/   GF77.20-P-4100S 
  Overhead control panel control module location/purpose/design/function   GF82.20-P-4101S