LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2005 >> ML500 >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking System -- 163 Chassis >> Basic Knowledge >> Acoustic alarm, function - GF80.50-P-4005GH

Acoustic alarm, function - GF80.50-P-4005GH

MODEL 163 with CODE (551a) Anti-theft alarm (ATA) 

The all-activity module (AAM) (N10)  operates relay F1k2 to activate the acoustic alarm. The relay links the alarm signal horn (H3)  to circuit 30. The signal provided is not a continuous signal but alternately a signal for one second and an interval for one second. If the acoustic alarm is not terminated beforehand, it stops after about 30 seconds.

If the acoustic alarm is activated by the panic switch  at the remote control key, the two-tone signal system (H1)  is actuated through the relay F1k2  in place of the alarm signal horn (H3)  . The duration and sequence of the alarm are as described above.

IMPORTANT

The alarm can be terminated by the activating ATA  or deactivating ATA  functions.

REFER TO BASIC KNOWLEDGE Visual alarm, function   GF80.50-P-4006GH 
REFER TO BASIC KNOWLEDGE Deactivating anti-theft alarm (ATA), function   GF80.50-P-2003GH 
REFER TO BASIC KNOWLEDGE Activating alarm by means of panic switch, function   GF80.50-P-2003GH 
REFER TO BASIC KNOWLEDGE All-activity module (AAM) position/task/design/function   GF54.21-P-4100GH