Remove/install SAM control unit with fuse and relay box, right front - AR54.21-P-1261GM
WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2015 Mercedes-Benz G550, 2014 Mercedes-Benz G550, 2013 Mercedes-Benz G550, 2012 Mercedes-Benz G550, and 2011 Mercedes-Benz G550. However, it is still accessible from the selected car via links, so may be relevant.
MODEL 463.202/222/236/237/243/244/245/246/247/248/249/250/254/270/271/303/306/309/322/323/332/333/336/340/341/346
Illustrated on model 463.333
| Remove/install | |||
|---|---|---|---|
| 1 | Activate service mode in Telematic Alarm Identification on Demand (emergency call system) (TELE AID) | AR82.95-P-0005-03GR | |
| Notes regarding the Tele-Aid emergency call system | Model 463.243/244/245/250/309/322/323/332/333, Model 463.247/248/254/270 up to 1.04.07 |
AH82.95-P-0001-01GA | |
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 2 | Disconnect battery ground line | Except model 463.236/248 with code (979) Special protection version. | AR54.10-P-0003G |
| Model 463.236/248 with code (979) Special protection version, with code (ZS6) Special protection version FB6, with code (E26) 100 Ah additional battery incl. cutoff relay, |
AR54.10-P-0003PM | ||
| Model 463.236/248 with code (979) Special protection version, with code (ZS7) Special protection version FB7, with code (E26) Additional battery 100 Ah incl. cutoff relay |
|||
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 3 | Remove glove compartment | AR68.10-P-1400GM | |
| 4 | Remove cover below dashboard | AR68.10-P-1520GM | |
| 5 | Unscrew nut (1) | ||
| 6 | Unscrew nut (2) | ||
| 7 | Remove front signal acquisition and actuation module (SAM) (N10/1) | ||
| 8 | Disconnect electrical connectors (3, 4) from front signal acquisition and actuation module (SAM) (N10/1) | ||
| Disconnecting lines from control units and fuse and relay boxes |
AR54.18-P-1261-01P | ||
| Connecting cables to control units and fuse and relay boxes. | AR54.18-P-1261-02P | ||
| 9 | Install in the reverse order | ||
| 10 | Deactivate service mode in TELE AID | AR82.95-P-0005-03GR | |
| Notes regarding the Tele-Aid emergency call system | Model 463.243/244/245/250/309/322/323/332/333, Model 463.247/248/254/270 up to 1.04.07 |
AH82.95-P-0001-01GA | |
| 11 | Read out fault memory and erase | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| 12 | Perform basic programming | AR00.19-P-0200P |