Charge battery - AR54.10-P-1130P
WARNING: This page is about a different car, the 2009 Mercedes-Benz CLK350 and 2008 Mercedes-Benz CLK350. However, it is still accessible from the selected car via links, so may be relevant.
MODEL 209
| Checking | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Check condition of battery | AR54.10-P-1129P | |
| Charging | |||
| 2 | Connect charger to battery | ||
| 3 | Charge battery | 10 % of battery capacity: e.g. max. 10 A charging current for a 100 Ah battery. Rapid charging: Charging current max. 50 % of battery capacity for 30 minutes: e.g. max. 50 A charging current for 100 Ah battery. |
|
| 4 | Disconnect battery charger | ||
| Checking | |||
| 5 | Test battery after charging, see:↓ | ||
| Check condition of battery | AR54.10-P-1129P |