Shut-off delay, function - GF83.70-G-3034A

WARNING: This page does not describe the selected car, but rather 22 other vehicles, including the 2015 Mercedes-Benz G550, 2014 Mercedes-Benz G550, 2013 Mercedes-Benz G550, 2012 Mercedes-Benz G550, and 2011 Mercedes-Benz G550. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 463 as of 1.6.94 with CODE (H12) Stationary heater Webasto Tele Thermo Top S 

Function prerequisites: 

Controlled heater operation  terminated or interrupted due to a malfunction. After the fuel metering pump (Y23)  has been switched off by the heater terminating the combustion the shut-off delay starts.

Shut-off delay function 

The shut-off delay serves for cooling down the heater and purging the combustion chamber. It runs for approx. 120 s:

  1. The circulating pump (A6m1), combustion air blower (A6m2)  and vehicle heater blower continue to run audibly. The air flowing out of the stationary heater exhaust outlet cools down slowly.
  2. After approx. 120 s the heater switches off the circulating pump (A6m1), combustion air blower (A6m2)  and vehicle heater blower. The shut-off delay is completed.
REFER TO BASIC KNOWLEDGE Termination of heater operation   GF83.70-G-2002A 
REFER TO BASIC KNOWLEDGE Controlled heater operation   GF83.70-G-2004A 
REFER TO BASIC KNOWLEDGE Interruption of heater operation   GF83.70-G-2005A 
REFER TO BASIC KNOWLEDGE Stationary heater malfunction shut-off   GF83.70-G-3037A 
REFER TO BASIC KNOWLEDGE Fuel metering pump   GF83.70-P-4008A 
REFER TO BASIC KNOWLEDGE Circulation pump   GF83.70-P-4003A 
REFER TO BASIC KNOWLEDGE Combustion air blower   GF83.70-P-4004A