Check quiescent current consumption - AR54.10-P-1030P
MODEL 203, 209, 463.243 /244 /245 /246 /247 /248 /249 /250 /254 /309 /322 /323 /332 /333
Shows model 463.249
| Checking | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 1.1 | Remove dust filter housing for heating/ventilation | ||
| AP83.00-P-8381P | |||
| 1.2 | Remove cup holder (A) | ||
| 1.3 | Remove battery box cover (B) | ||
| 2.1 | Preparing test with quiescent current retention unit | AR54.10-P-1030-01P | |
| *WH58.30-Z-1001-09A | |||
| *WH58.30-Z-1012-09A | |||
| 2.2 | Prepare test without quiescent current retention unit | AR54.10-P-1030-02P | |
| *WH58.30-Z-1001-09A | |||
| 3 | Switch off all consumers | Switch off stationary heater. Switch off car phone. Switch off radio. Switch off interior protection. Switch off vanity mirror Switch off reading light. Turn rotary light switch to "0" position. Close doors, the interior illumination must go out automatically after a few seconds. With Comand: Remove CD-ROM from Comand, switch off Comand. |
|
| Risk of injury to skin and eyes caused by handling hot or glowing objects. | Wear safety gloves, protective clothing and safety glasses, if necessary. | AS00.00-Z-0002-01A | |
| 4 | Check whether auxiliary water pump is operating | Auxiliary water pump operating:↓ Do not commence quiescent current test until pump has switched off. |
|
| 5.1 | Remove cover below instrument panel (right) | Model 463.243 /244 /245 /246 /247 /248/ 249 /250 /254 /309 /322 /323 /332 /333. |
AR68.10-P-1520GM |
| 6 | Testing quiescent current | AR54.10-P-1030-03P | |
| Figure | |||
| Figure | |||
| *WH58.30-Z-1001-09A | |||
| If specification for total quiescent current is not achieved: ↓ | |||
| Determine circuit with excessive quiescent current consumption. | AR54.10-P-1030-04P | ||
| Specification not achieved: ↓ Determine fuse-protected components with increased quiescent current consumption. |
AR54.10-P-1030-05P | ||
| Specification not achieved: ↓ Determine non-fuse protected components with increased quiescent current consumption. |
AR54.10-P-1030-06P | ||
| To check, re-test quiescent current. | AR54.10-P-1030-03P | ||
| 7 | Render electrical system operational | ||
| Perform basic programming. | AR00.19-P-0200P |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
| WH58.30-Z-1012-09A | Quiescent current retention unit |