ME-SFI safety fuel shut-off function - GF07.61-P-3018GS
ENGINE 111.951 /952 /955 /956 /957 /958 /982 /983 with CODE (925) low emission EURO3
Safety fuel shut-off is active:
- if mechanical faults exist in the actuator, to limit engine speed by shutting off the injectors (e.g. 1400 rpm).
- in the absence of engine speed signals TN, to interrupt the fuel pump operation.
- The ME-SFI control module is supplied with a crash signal by the airbag control module if the airbag is deployed (frontal crash). In this case, the ME-SFI control module switches off the fuel pump.
| ME-SFI control module position / task / design / function | GF07.61-P-5000GS | ||
| Crankshaft position sensor position/task/design/function | GF07.04-P-4116F | ||
| Electronic accelerator function | GF30.20-P-3010E | ||
| Fuel pump actuation function | GF07.61-P-3012GS | ||
| ME-SFI engine speed signal function | GF07.61-P-3017GS | ||
| Electronic accelerator pedal emergency running mode function | GF30.20-P-4026E |