ME-SFI ignition system - Testing electrical system - AD07.61-P-6001A
ENGINES 112.910,
112.911 up to 31.5.00,
112.920,
112.921 up to 31.5.00,
112.923,
112.940 /941 /942 up to 31.5.00,
112.943
| Hazard from contact with parts conducting high voltages. | Do not touch parts which conduct high voltages. Persons who wear electronic implants (e.g. heart pacemakers) must not carry out work on the ignition system. | AS15.10-Z-0001-01A | |
| Lethal hazard from being drawn into rotating vehicle parts | Do not reach into rotating parts. Wear closed and close-fitting work clothes. Secure area of rotating vehicle components against unauthorized access. |
AS00.00-Z-0004-01A | |
| Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel. | No fire, sparks, naked flames or smoking. Pour fuels only into suitable and appropriately marked containers. Wear protective clothing when handling fuel. |
AS47.00-Z-0001-01A | |
| When disconnecting the connectors on the ME-SFI control module, disconnect the middle connector first and when connecting, connect the middle connector D last. | |||
| Connection and use of testing equipment | AD00.00-P-1000AZ | ||
| Gasoline injection and ignition system (ME-SFI) - diagnosis - previous knowledge | AD07.61-P-2000A | ||
| Notes on tester/test connection column The numbers entered in parentheses, such as, for example in => 1.0 (2A) have the following meaning: A = Connector A in the circuit diagram 2 = Socket 2 in the circuit diagram |
|||
| Gasoline injection and ignition system (ME-SFI) - diagnosis - diagnostic trouble code memory | Fault codes from P0000 to P0299 | AD07.61-P-4000A | |
| Gasoline injection and ignition system (ME-SFI) - diagnosis - diagnostic trouble code memory | Fault codes from P0300 to P0699 | AD07.61-P-4000AA | |
| Gasoline injection and ignition system (ME-SFI) - diagnosis - diagnostic trouble code memory | Fault codes from P0700 to P1747 | AD07.61-P-4000AB | |
| a | Ignition: OFF | ||
| b | Connect test wiring harness with socket box at ME-SFI control module (N3/10) according to connection diagram. | ||
| Checking | |||
| 1 | ME-SFI control module terminal 30 - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-01A | |
| 2 | ME-SFI control module terminal 87 - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-02A | |
| 3 | Ignition coil (T1/1) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-03A | |
| 4 | Ignition coil (T1/2) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-04A | |
| 5 | Ignition coil (T1/3) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-05A | |
| 6 | Ignition coil (T1/4) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-06A | |
| 7 | Ignition coil (T1/5) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-07A | |
| 8 | Ignition coil (T1/6) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-08A | |
| 9 | Crankshaft position sensor - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-09A | |
| 10 | Camshaft Hall sensor - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-10A | |
| 11 | Primary voltage (T1/1) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-11A | |
| 12 | Primary voltage (T1/2) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-12A | |
| 13 | Primary voltage (T1/3) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-13A | |
| 14 | Primary voltage (T1/4) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-14A | |
| 15 | Primary voltage (T1/5) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-15A | |
| 16 | Primary voltage (T1/6) - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-16A | |
| 17 | Ignition voltage - Testing electrical system, ME-SFI ignition system | AD07.61-P-6001-17A |