Adaptive damping system (ADS II) test of hydraulic system level controller overflow valve - AD32.32-P-7006-02A
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Opening pressure of bypass valve | 250 bar at level controller connection S2 |
Engine: Idling Level controller lever in position "F" = Fill |
Model 140 120-153 bar Model 210 120-140 bar |
|