Removing and installing TELE AID emergency call system control module - AR82.95-P-0005D: Notes
MODEL 208.4 with CODE (347) TELE AID emergency call system (D2B)
European version
Illustrated on permanently installed telephone code 316
| Removal, installation | |||
| 1 | Connect quiescent current retention unit | *WH58.30-Z-1012-09A | |
| 2 | Disconnect ground lead from battery | AR54.10-P-0003A | |
| 3 | Remove rear assembly wall | AR68.74-P-1000KA | |
| 4 | Pull connection lead and D2B connection lead off of TELE AID control module (A35/8) | AR82.95-P-0005-01A | |
| 5 | Unscrew TELE AID control module (A35/8) from mount with 4 screws (1) and pull out | ||
| 6 | Install in opposite order |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation |
|---|---|
| WH58.30-Z-1012-09A | Quiescent current retention unit |