Home >> Mercedes Benz >> 1997 >> E320 >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking System - Self-Diagnostic System - 210 Chassis >> Self-Diagnostic System >> Radio frequency locking/remote central locking (RFL/RCL) diagnosis, function check of actual values, drive authorization - AD80.35-P-3003A

Radio frequency locking/remote central locking (RFL/RCL) diagnosis, function check of actual values, drive authorization - AD80.35-P-3003A

MODEL 202 as of 1.6.97, 208, 210.081 /281, 210 as of 1.3.97 

  Prerequisites for interrogating actual values     
I Fuses in order    
II Battery voltage > 11 V    
III Voltage supply of control modules and CAN data buses in order   Body DM Volume 2
IV Connect Hand-Held Tester to data link connector (DTC readout) (X11/4) in accordance with connecting diagram   AD00.00-P-1000AZ
Test step/ A Scope of test  HAND-HELD TESTER Operation/Requirement  Specified value  Possible cause/Remedy 
1 EZS Ignition key YES AD80.35-P-6000-33A 
Voltage supply Terminal 15 position ON OFF    NO AD80.35-P-6000-34A 
2 EZS Insert key UNLOCKED AD80.35-P-6000-33A 
Electric steering column locking (ELVR) 1 in EZS
Remove key from EZS
  LOCKED AD80.35-P-6000-34A 
3 EZS Insert key UNLOCKED AD80.35-P-6000-33A 
Electric steering column locking (ELVR) 2 in EZS
Remove key from EZS
  LOCKED AD80.35-P-6000-34A 
4 EZS Insert key YES Electronic ignition switch control module (N73)
Key inserted in EZS in EZS
Remove key from EZS
  NO  
5 EZS Insert key YES Electronic ignition switch control module (N73)
Start message received from transmitter key in EZS
Remove key from EZS
  NO  
6 EZS Insert key YES Transmitter key
Authentication check carried out (Transmitter key - EZS) in EZS
Remove key from EZS
  NO  
7 EZS Insert key NO Electronic ignition switch control module (N73)
Energy supply for transmitter key switch off (coil in EZS) in EZS (during authentication check Key - EZS)  
      YES  
8 EZS Insert key YES Electronic ignition switch control module (N73)
HO auxiliary contact in EZS, turn clockwise slightly
Ignition: On 
  NO  
9 EZS Insert key ON AD80.35-P-6000-35A 
Terminal 50 in EZS, turn clockwise up to stop
Release key
  OFF