Special signal system diagnosis, fault memory - AD82.25-P-4003A
MODEL 202 as of 1.6.97, 210.081 /281, 210 (except 210.081 /281) as of 1.3.97
Official and emergency vehicles
| Special signal system diagnosis, advanced information | AD82.25-P-2003A | ||
| Connect Hand-Held Tester (HHT) and read out fault memory | AD00.00-P-2000-03A | ||
| Fault memory | |||
| Fault code |
Fault text | Possible cause/Note | Remedy |
| No fault | No fault recognized | If there is a complaint nevertheless, carry out diagnosis, testing electrical system. | AD82.25-P-6003A |
| B1000 | Control module defective | Special vehicle multifunction control module (SVMCM) (N26/9) defective. | N26/9 |
| B1010 | Undervoltage | Undervoltage recognized. | Check control module voltage supply ↓ AD82.25-P-6001-05A |
| B1011 | Overvoltage | Overvoltage recognized | Check control module voltage supply ↓ AD82.25-P-6001-05A |
| B1499 | Main-beam headlamps | Cable, main-beam headlamps output | AD82.25-P-6003-01A |
|
Cable Headlamp flasher/highlamp switch (S4s2) sticks or was operated for more than 20 seconds |
AD82.25-P-6003-02A | |
| B1960 | Blue light (E25/5) -KnM, |
Cable, blue light/two-frequency flashing system | Test blue light/two-frequency flashing system in accordance with manufacturer's specifications |
| B1961 | Emergency alarm activation switch (S62/16, 17, 18) | Switch sticks or was operated for more than 20 seconds | AD82.25-P-6002-01B AD82.25-P-6002-02A |
| Emergency alarm cancellation switch (S62/5) Emergency alarm activation switch (S62/16,17,18) |
Cable open-circuit. | AD82.25-P-6002-01B |