LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 1997 >> E320 >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System - Self-Diagnostic System - 210 Chassis >> Self-Diagnostic System >> Digital data bus (D2B) diagnosis, fault memory - AD82.00-P-4000A

Digital data bus (D2B) diagnosis, fault memory - AD82.00-P-4000A

MODEL 129 as of 1.6.98, 168 as of 1.9.98, 170, 202, 208, 210 as of 1.6.98, 215, 220 

  Digital data bus (D2B), diagnosis, previous knowledge   AD82.00-P-2000A 
  Interrogate the actual configuration of control modules in the vehicle using Hand-Held Tester (HHT)    
  Connect Hand-Held Tester (HHT), read out fault memory Except model 215, 220 AD00.00-P-2000-03A
  Fault memory     
Fault code  Possible cause  Notes  Remedy 
No fault code No fault code recognized However, if there is a complaint: ↓
Digital data bus, diagnosis, troubleshooting
AD82.00-P-5000A 
N1111 Optical fiber defective No data can be transferred between radio or COMAND and control module to position X AD82.00-P-2000-01A 
  Control module transmitter unit defective
Control module receiver unit defective
  AD82.00-P-2000-02A 
N1112 Optical fiber defective No data transfer between radio and D2B predecessor AD82.00-P-2000-01A 
  Control module transmitter unit defective
Control module receiver unit defective
  AD82.00-P-2000-02A 
N1113 Optical fiber defective D2B data transfer faulty AD82.00-P-2000-01A 
  Control module transmitter unit defective
Control module receiver unit defective
  AD82.00-P-2000-02A 
N1114 Head unit cannot be incorporated in the D2B ring D2B initialization faulty.
Erase fault memory, switch system on again and read out fault memory
If fault persists, replace control module
N1115 A control module at position X cannot be incorporated in the D2B ring due to faulty initialization D2B initialization of control module faulty. AD82.00-P-2000-01A 
    Erase fault memory, switch system on again and read out fault memory If fault persists, replace control module
N1116 D2B component at position X failed (bypass mode) Internal fault in control module at position X. AD82.00-P-2000-01A 
    Erase fault memory, switch system on again and read out fault memory. If fault persists, replace control module
N1117 D2B initialization of a D2B component faulty. Erase fault memory, switch system on again and read out fault memory
  1. Fault also exists in other control modules of the D2B ring:↓

    Replace head unit

  2. No fault in other control modules of the D2B ring:↓

    Replace control module

N1118 D2B initialization of a D2B component faulty. Erase fault memory, switch system on again and read out fault memory
  1. Fault also exists in other control modules of the D2B ring:↓

    Replace head unit

  2. No fault in other control modules of the D2B ring:↓

    Replace control module

N1141 Radio:
Specified/actual configuration of the D2B ring differ
  Re-configure system